Journal of Clinical and Diagnostic Research, ISSN - 0973 - 709X

Users Online : 45354

Original article / research
Year : 2017 | Month : September | Volume : 11 | Issue : 9 | Page : YC09 - YC12

Hand-Held Dynamometer is a Reliable Tool to Measure Trunk Muscle Strength in Chronic Stroke

Suruliraj Karthikbabu, Mahabala Chakrapani

1. Associate Professor, Department of Physiotherapy, School of Allied Health Sciences, Manipal University, Bengaluru, Karnataka, India. 2. Associate Dean and Professor, Department of Internal Medicine, Kasturba Medical College, Manipal University, Mangalore, Karnataka, India.

Correspondence Address :
Dr. Suruliraj Karthikbabu
Associate Professor, Department of Physiotherapy, SOAHS, Manipal University,
Manipal Hospital, HAL Airport Road, Bengaluru-560017, Karnataka, India.
E-mail: karthikbabu78@gmail.com

Abstract

Introduction: Patients with chronic stroke show atypical coordination of trunk movement and they find difficulty during bed mobility and transfer skills due to weakness of trunk muscles. Routine bedside clinical examination fails to quantify the trunk muscle strength in patients with stroke. Handheld dynamometer is widely administered to quantify the strength of extremities, but its reliability on testing the trunk muscles strength is limited.

Aim: This study aimed at examining the reliability of hand-held dynamometer to quantify the strength of trunk muscle groups in chronic stroke.

Materials and Methods: This reliability study was conducted in outpatient clinical settings. Patients with chronic stroke aged between 30 and 80 years and an ambulatory capacity of 10-meter distance volunteered in the study. The strength of trunk flexors, extensors, rotators towards most and least affected sides and bilateral lateral flexors was examined by break test using hand-held dynamometer and the isometric strength was reported in pounds (lb.). These tests were carried out by two physical therapists independently at two time points and the assessment procedure was standardized. Pearsonís correlation test was conducted to observe the reliability of dynamometer strength testing i.e., internal consistency of the measure and intra-class correlation coefficient (r).

Results: Of the 85 study participants, 51 of them had most trunk involvement on the left side and 34 had it on the right side. This study showed an excellent intra-rater (0.88-0.98) and inter-rater (0.84-0.96) reliability of trunk muscle strength testing using hand-held dynamometer.

Conclusion: Hand-held dynamometer showed excellent intra and inter tester reliability to quantify the trunk muscle strength in patients with chronic stroke. So this tool can easily be administered in clinical and rehabilitation settings for diagnostic and prognostic purposes.

Keywords

Neuro-physiological procedures, Mobility functioning, Trunk weakness

How to cite this article :

Suruliraj Karthikbabu, Mahabala Chakrapani. HAND-HELD DYNAMOMETER IS A RELIABLE TOOL TO MEASURE TRUNK MUSCLE STRENGTH IN CHRONIC STROKE. Journal of Clinical and Diagnostic Research [serial online] 2017 September [cited: 2018 Jan 23 ]; 11:YC09-YC12. Available from
http://www.jcdr.net/back_issues.asp?issn=0973-709x&year=2017&month=September&volume=11&issue=9&page=YC09-YC12&id=10672

DOI and Others

DOI: 10.7860/JCDR/2017/28105.10672

Date of Submission: Apr 19, 2017
Date of Peer Review: Jun 27, 2017
Date of Acceptance: Aug 21, 2017
Date of Publishing: Sep 01, 2017

FINANCIAL OR OTHER COMPETING INTERESTS: None.

JCDR is now Monthly and more widely Indexed .
  • Emerging Sources Citation Index (Web of Science, thomsonreuters)
  • Index Copernicus ICV 2016: 132.37
  • SCOPUS
  • Academic Search Complete Database
  • Directory of Open Access Journals (DOAJ)
  • EBSCOhost
  • Embase & EMbiology
  • Google Scholar
  • HINARI Access to Research in Health Programme
  • Indian Science Abstracts (ISA)
  • Journal seek Database
  • Google
  • Popline (reproductive health literature)
  • www.omnimedicalsearch.com