JCDR - Register at Journal of Clinical and Diagnostic Research
Journal of Clinical and Diagnostic Research, ISSN - 0973 - 709X
Dentistry Section DOI : 10.7860/JCDR/2014/9160.5173
Year : 2014 | Month : Nov | Volume : 8 | Issue : 11 Full Version Page : ZC83 - ZC87

Comparative Evaluation of Microleakage of Lingual Retainer Wires Bonded with Three Different Lingual Retainer Composites: An In Vitro Study

Smita Nimbalkar-Patil1, Anna Vaz2, Pravinkumar G. Patil3

1Lecturer, Department of Orthodontics, Faculty of Dentistry, MAHSA University, Kuala Lumpur, Malaysia.
2Professor, Department of Orthodontics and Dentofacial Orthopedics, PMNM Dental College and Hospital, Bagalkot, Karnataka, India.
3Senior Lecturer, School of Dentistry, International Medical University, Kuala Lumpur, Malaysia.


NAME, ADDRESS, E-MAIL ID OF THE CORRESPONDING AUTHOR: Dr. Smita Nimbalkar-Patil, Covillea Condominium, B-23-3A, Bukit Jalil, Near IMU, Kuala Lumpur, Malaysia-57000.
Phone: +601135022041,
E-mail: pravinandsmita@gmail.com
Abstract

Objective: To evaluate microleakage when two types of retainer wires were bonded with two light cured and a self cured lingual retainer composites.

Materials and Methods: Total 120 freshly extracted human mandibular incisor teeth were collected and separated into six subgroups of 20 teeth each. Two different wires, a 0.036 inch hard round stainless steel (HRSS) wire sandblasted at the ends and 0.0175 inch multistranded wire bonded onto the lingual surfaces of the incisors with three different types of composite resins of 3M company; Concise Orthodontic (self-cure), Transbond XT (light-cure) and Transbond LR (light-cure). Specimens were further sealed with a nail varnish, stained with 0.5% basic fuchsine for 24 hours, divtioned and examined under a stereomicroscope, and scored for microleakage for the enamel-composite and wire-composite interfaces. Statistical analysis was performed by Kruskal-Wallis and Mann-Whitney U-tests.

Results: For HRSS wire, at the enamel-composite interface, the microleakage was least with Transbond LR followed by Concise Orthodontic and greatest for Transbond XT (p<0.05). At the wire composite interface too, the microleakage was in order of Transbond LR<Concise Orthodontic<Transbond XT. For the multistranded wire, at the enamel-composite interface, the microleakage was least with Transbond LR followed by Concise Orthodontic and Transbond XT (p<0.05). At the wire composite interface too, it was seen that microleakage was the least with Transbond LR followed by Concise Orthodontic and Transbond XT.

Conclusion: Transbond LR in combination with 0.0175 inch multistranded wire showed least microleakage amongst the groups studied.

Keywords

Introduction

Retention is one of the controversies of modern orthodontics, with uncertainty being the only certainty [1]. The cases that will relapse cannot be predicted and that indefinite retention is necessary if the finished result of active orthodontic treatment is to be maintained [2]. The clinician, in consultation with each patient, must determine the appropriate retention regimen for each case [3]. Initially the appliances for retention of post treatment tooth position proposed were based on banded fixed appliances [4]. Removable retainers were subsequently advocated for use [5]. Bonded lingual retainers are fabricated in various designs which consist of a combination of different wires in various sizes and of different compositions and physical structures [6]. The multi-stranded wire has proved to be superior as compared to plain, round wires due to its irregular surface which offers increased mechanical retention for the composite without the need of the placement of retentive loops [7]. Different composites have been described for use in this technique including both restorative materials and orthodontic bonding materials [8].Concise, a conventional restorative composite based on Bis-GMA is a commonly used self cure composite resin for bonded retainers [9]. Concise orthodontic is manufactured with decreased viscosity to aid handling, however it was unclear in some studies in the literature whether this or restorative material was used [9]. The fabrication of lingual retainers require meticulous and time consuming work, therefore, many clinicians prefer to use visible light-cured composites over chemically cured ones [10]. It has been shown that Concise orthodontic and Transbond XT (a conventional light cured orthodontic composite) compare favorably because of their abrasion resistance and strength [11]. Transbond LR is a highly filled light cured composite which is specially manufactured for lingual retainers [12]. Larger round stainless steel wires are seen to fail more often than thinner stranded wires [13]. The most common failure type is detachment at the composite-wire interface because of insufficient adhesive over the wire or unfavorable occlusal contacts which results in abrasion of the composite [14]. Microleakage beneath bonded orthodontic attachments may be a reason for failures too. In the literature, different band cements [15], light sources [16] and brackets [17] have been evaluated for microleakage but these studies primarily focused on enamel demineralization. Microleakage beneath composites is particularly important in orthodontics especially for lingual retainer adhesives, as they are exposed to the oral cavity and are intended to serve in mouth for a long period of time. Gap formation contributes to microleakage, permitting the passage of bacteria and oral fluids into oral cavity [18]. Though Concise orthodontic, Transbond XT and Transbond LR are almost comparable in hardness, they have not been collectively evaluated for microleakage at the enamel-composite and wire-composite interface. Hence this study was planned to evaluate microleakage with respect to the third generation sandblasted 0.036 inch Hard Round Stainless Steel wire and a second generation flexible spiral 0.0175 inch co-axial wire.

Materials and Methods

Total 120 mandibular incisors extracted for periodontal involvement or any therapeutic purposes were collected from Department of Oral and Maxillofacial Surgery. Immediately before bonding, the teeth were cleaned using an ultrasonic-scaler to remove tissue tags, plaque. The teeth were polished using non-fluoridated, oil- free, pumice paste rinsed with water and dried with an oil and moisture free air spray for 30 seconds. Two different wires, a 0.036 inch hard round stainless steel wire (HRSS) sandblasted at the ends and 0.0175 inch multistranded wire (M) bonded onto the lingual surfaces of the incisors with three different types of composite resins; (1) a self curing composite, Concise Orthodontic, (2) a light cured composite used for orthodontic bonding, Transbond XT 3) a light cured composite specifically manufactured for lingual retainer bonding, Transbond LR.

All 120 teeth were divided into 3 main groups and further 2 subgroups in each group (making total 6 subgroups with 20 teeth each) [Table/Fig-1]. The bonding method for each material has been described in [Table/Fig-2]. After bonding, the apices of the teeth were sealed with sticky wax, rinsed under tap water and air dried. All the teeth were then kept in 0.5% solution of basic fuchsine for 24 hours at room temperature. The samples were brushed off to remove superficial dye and the composite bulk was sectioned parallel to the lingual retainer wire at low speed with a water cooled diamond disc [Table/Fig-3]. The specimens were then evaluated for dye penetration along the enamel-composite interface. The wires were then gently removed from the composite bulk and the dye penetration was evaluated between the adhesive-wire interface on mesial and distal side. Direct measurement of the length of the penetrated dye was made using a digital caliper with an accuracy of 0.01 mm [Table/Fig-4a,4b]. The measurements were repeated by another observer and subjected to statistical evaluation (Kappa test) to evaluate for inter-examiner method error.

The Kappa scores for assessment of microleakage for Concise Orthodontic, Transbond XT, and Transbond LR were calculated. The inter examiner kappa scores for assessment of microleakage were high, with all values greater than 0.8 [Table/Fig-5]. It indicates fair amount of agreement between observations taken by two observers, thus validating the procedure. Descriptive statistics including mean, standard deviation, minimum and maximum values of microleakage are presented in [Table/Fig-6]. Microleakage between the two wires 0.036” HRSS wire and 0.0175” coaxial wire was assessed at two sites (mesial and distal) and at two interfaces (enamel-composite and wire-composite).

Results

Microleakage utilizing the three composites with respect to 0.036” HRSS wire:-

For HRSS wire, at the enamel-composite interface, it was seen that microleakage was least with Transbond LR followed by Concise Orthodontic and greatest for Transbond XT. These values for microleakage for three composites studied were statistically significant (p<0.05) [Table/Fig-7] and when a pair wise evaluation was carried out, significant differences (p<0.05) [Table/Fig-8] were noted between the groups for both mesial and distal ends of the wire at wire composite interface. At the enamel composite interface too, it was seen that microleakage was the least when Transbond LR was used followed by Concise Orthodontic and Transbond XT.

Microleakage utilizing the three composites with respect to 0.0175” multistranded wire:-

For the 0.0175 multistranded wire, at the enamel-composite interface, it was seen that microleakage was least with Transbond LR followed by Concise Orthodontic and greatest for Transbond XT (p<0.05) [Table/Fig-7]. At the wire composite interface too, it was seen that microleakage was the least with Transbond LR followed by Concise Orthodontic and Transbond XT [Table/Fig-7]. When the microleakage values at the enamel composite interface was compared with that at the wire composite interface (for both the wires), it was noted that the microleakage at the two interfaces were more or less equal.

At the enamel-composite interface, all the materials, irrespective of the wire used performed well with little or no microleakage. The difference was not statistically significant. At the wire-composite interface however, the flexible multistranded wire showed less microleakage when compared to the HRSS wires [Table/Fig-4a,4b]. This reduced microleakage was evident when Concise and Transbond XT was used to bond the wires. When Transbond LR is used, the amount of microleakage was low with both the wires and there was no statistically significant difference between the two wires [Table/Fig-4a,4b].

Discussion

In orthodontics, various devices for post treatment retention have evolved from conventional, removable wire retainers to esthetic, more hygienic, permanent or semi-permanent bonded lingual retainers, which are designed to serve in the mouth for a long period of time. Many in vitro studies [9,14,19] have suggested that Concise Orthodontic is a preferred composite resin for lingual groupsretainer fabrication because greater force is required to detach the wire from the material and the material has good in vitro abrasion resistance [11]. Transbond LR, a highly filled and a specially manufactured light cure composite for lingual retainers is also recommended for use when longevity and durability is required [12]. It has been shown that Concise Orthodontic and Transbond XT, compares favorably because of its abrasion resistance and strength [11]. The microleakage was assessed with the help of dye penetration method which involves exposure of samples to a dye solution [8,10,18,20] and then viewing cross sections under stereomicroscope [21]. Because of the range of bacteria sizes, dye used was 0.5% Basic fuchsine solution as it is realistic agent to identify a clinically relevant gap [22]. It was determined by direct measurement using an electronic digital caliper of accuracy 0.01mm [8,10,18,20].

At the enamel-composite as well as wire-composite interface and utilizing the 0.036” HRSS wire the microleakage seen in Transbond LR was significantly lower than that of Concise Orthodontic and Transbond XT. This decrease in microleakage could probably be attributed to the filler loading of the resin [15]. Transbond LR is claimed to have a filler load of 75-85% [15], Concise 80%, [19] Transbond XT 70-80% [15]. The filler particle size and the load is seen to influence the polymerisation shrinkage of material and this could influence the microleakage [15]. These values of microleakage were consistently higher on the mesial side as against the distal side and this could probably be attributed to the presence of thick round wire and its related difficulty of forming the composite as smooth as the distal portion. This view is in accordance with Uysal [20]. The microleakage values were not in agreement with that obtained by Uysal et al,. [20], Baysal et al., [10] and Yagci et al., [18]. These variations suggest the importance of other factors, such as study design, difference in pretreatment of wire before bonding to lingual surface of teeth, different methods of enamel pretreatment in determining microleakage.

According to this study, Concise Orthodontic proved to be a material superior to Transbond XT owing to the reduced marginal leakage. Concise Orthodontic is chemically cured and where increased working time through light curing is preferred, Transbond XT is a viable option. Polymerization shrinkage is one important factor to be considered and it could be a cause for failure of fixed lingual retainers (detachment at wire-composite interface)[15,21]. At the enamel-composite as well as wire-composite interface and utilizing the 0.0175” multistranded wire, the pairwise comparison of microleakage values of the three groups revealed Transbond LR to have a significantly lesser microleakage than Transbond XT and Concise Orthodontic. For the 0.0175” multistranded wire, microleakage values at the enamel-composite interface and wirecomposite interface were more or less equal. When the two wires were compared to each other with respect to the three composite resins, it was noted that the multistranded wire performed better than the stiff 0.036 inch HRSS wire with regard to microleakage. Hence, as a result of this study, with respect to microleakage, TransbondLR has got reduced polymerization shrinkage and consequent microleakage. This is in accordance with Uysal et al., [8].

Foek et al., [23] studied the bond strength of a stainless steel orthodontic wire vs various fiber-reinforced composites (FRC) used as orthodontic retainers on enamel and confirmed that regardless of application mode, stainless steel orthodontic bonded retainers delivered higher bond strengths than those of fiber retainers. Intensity of the different curing light should also be taken into consideration as high-intensity light curing units show statistically significant microleakage at the composite/wire interface and therefore may not be safe for use in bonding for lingual retainer wires [24]. The limitation of the study are: (1) the oral environmental conditions cannotbe simulated outside accurately to examine the micro-leakage, (2) Chances of damaging the stained areas while sectioning the teeth, (3) Application mode and the flow of the materials tested are different and may influence the micro-leakage values.

The details of subgroups

CompositeConcise ( Group I)Transbond XT (Group II )Transbond LR (Group III )
Wire0.036” SS wire sandblasted at ends(a)0.0175” Coaxial wire(b)0.036” SS wire sandblasted at ends(a)0.0175” Coaxial wire(b)0.036” SS wire sandblasted at ends(a)0.0175” Coaxial wire(b)
GroupsI(a)I(b)II(a)II (b)III(a)III (b)
Teeth202020202020

Materials application methods

GroupMaterial37% Ortho-phosphoric Acid etching TimePrimingComposite Application
PrimerLight curing timeCompositeLight curing time
IConcise15 SecConcise Resin A and Resin B (mixing for 10 Sec)-------Concise Orthodontic paste A and paste B (mixing for 10 Sec)-------
IITransbond XT30 SecTransbond XT primer10 SecTransbond XT primer orthodontic composite20 Sec
IIITransbond LR30 SecTransbond XT primer10 SecTransbond Lingual Retainer composite20 Sec

Method to section the samples parallel to the lingual retainer wire

Direct measurement of the length of the penetrated dye at enamel-composite interface. Note the wire is not yet removed

Direct measurement of the length of the penetrated dye at wire-composite interface after removal of the wire

examiner Kappa scores for assessment of micro-leakage amongst three composites using 0.036” Hard Round Stainless Steel Wire* and 0.0175” coaxial wire

(Group I) Concise Orthodontic(Group II) Transbond XT(Group III) Transbond LR
0.036” SS wire* sandblasted at ends (a)0.0175” Coaxial wire (b)0.036” SS wire* sandblasted at ends (a)0.0175” Coaxial wire (b)0.036” SS wire* sandblasted at ends (a)0.0175” Coaxial wire (b)
E-C interfaceMesial0.99±0.220.99±0.220.98± 0.220.95±0.220.97± 0.220.97 ±0.22
W-C interface0.88 ±0.220.98±0.220.94± 0.220.98±0.220.97± 0.220.99± 0.22
E-C interfaceDistal0.99 ±0.220.99±0.220.95± 0.230.89±0.220.96 ±0.220.96 ±0.22
W-C interface0.99 ±0.22-0.96± 0.22-0.96± 0.22-

Microleakage values for 0.036” Hard Round Stainless Steel Wire and 0.0175” coaxial wire in different groupsretainer

0.036” SS wire sandblasted at the ends0.0175 Coaxial Wire
MeanStd.Dev.MinimumMaximumMeanStd.Dev.MinimumMaximum
Group I (Concise Orthodontic)E- C interfaceMesial0.940.440.581.860.980.410.41.83
Distal0.140.3801.230.090.0800.27
W-C interfaceMesial1.040.360.461.660.890.260.661.65
Distal0.280.3700.960000
Group II (Transbond XT)E- C interfaceMesial1.320.340.371.91.290.250.651.68
Distal0.260.380.061.360.120.2900.9
W-C interfaceMesial1.320.260.881.771.070.350.351.65
Distal0.530.2200.90000
Group III (Transbond LR )E- C interfaceMesial0.610.390.661.740.670.380.131.21
Distal0.030.1100.510.020.0600.25
W-C interfaceMesial0.730.260.361.250.630.310.111.22
Distal0.050.1400.560000

Comparison of microleakage with respect to three composites at wire composite interface on mesial and distal sides by Kruskal Wallis-ANOVA test

WireIntefaceSurfaceCompositesMeansStd.Dev.Sum of ranksH-valuep-value
0.036” HRSSEnamel-CompositeMesialGroup Ia (Concise Orthodontic)0.940.44604.523.29780.0429*
Group IIa (Transbond XT)1.320.34675.5
GroupIIIa (Transbond LR)0.610.39550
DistalGroup Ia(Concise Orthodontic)0.140.3875735.46070.0000*
Group IIa (Transbond XT)0.260.38534
GroupIIIa (Transbond LR)0.030.11239
Wire-CompositeMesialGroup Ia (Concise orthodontic)1.040.3655625.06560.0000*
Group IIa (Transbond XT)1.320.26833
Group IIIa (Transbond LR)0.730.26300
DistalGroup Ia (Concise orthodontic)0.280.3759221.72550.0000*
Group IIa (Transbond XT)0.530.22857.5
Group IIIa (Transbond LR)0.050.14380.5
0.0175 inch coaxial wireEnamel-CompositeMesialGroup Ib(Concise Orthodontic)0.980.41547.515.11770.0005*
Group IIb (Transbond XT)1.290.25849
Group IIIb (Transbond LR)0.670.38469.5
DistalGroup Ib(Concise Orthodontic)0.090.08785.511.19380.0037*
Group IIb (Transbond XT)0.120.29534
Group IIIb (Transbond LR)0.020.06510.5
Wire-CompositeMesialGroup Ib (Concise Orthodontic)0.890.26620.514.94330.0006*
Group IIb (Transbond XT)1.070.35818
Group IIIb (Transbond LR)0.630.31391.5
DistalGroup Ib (Concise Orthodontic)0061001
Group IIb (Transbond XT)00610
Group IIIb (Transbond LR)00610

Comparison of microleakage with respect to 0.036” Hard Round Stainless Steel wire* and 0.0175” multistranded wire£ at enamel composite interface by Mann-Whitney U test

IntefaceSurfaceCompositesWiresSum of ranksU-valueZ-valueH-value
Enamel-composite interfaceMesialGroup I(Concise Orthodontic)HRSS378112-0.68040.3621
M322
Group II (Transbond XT)HRSS437173-0.73040.4652
M383
Group III (Transbond LR)HRSS541.568.5-1.55710.5732
M498.5
DistalGroup I(Concise Orthodontic)HRSS35133-0.69750.3721
M302
Group II (Transbond XT)HRSS38624-0.76080.5221
M334
Group III (Transbond LR)HRSS409.5187.5-0.01350.7892
M378.5
Wire-composite interfaceMesialGroup I(Concise Orthodontic)HRSS503.5106.5-2.52920.0114*
M316.5
Group II (Transbond XT)HRSS499111-2.40750.0161*
M321
Group III (Transbond LR)HRSS446.5163.5-0.98730.3235
M373.5
DistalGroup I(Concise Orthodontic)HRSS490120-2.1640.0305*
M330
Group II (Transbond XT)HRSS59020-4.8690.0000*
M230
Group III (Transbond LR)HRSS440170-0.81150.4171
M380

Conclusion

Transbond LR in combination with 0.0175 inch multistranded wire showed least microleakage amongst all wire-composite combinations studied.

References

[1]MA Bramante, Controversies in orthodontic. Dent Clin North Am 1990; 34: 91- 102. As cited from Bearn DR. Bonded orthodontic retainers: A review Am J Orthod Dentofac Orthop 1995 108:207-13.  [Google Scholar]

[2]RS Nanda, SK Nanda, Considerations of dentofacial growth in long-term retention and stability: is active retention needed? Am J Orthod Dentofac Orthop 1992 101:297-303.  [Google Scholar]

[3]BU Zachrisson, Excellence in finishing. J Clin Orthod 1986; 20:460-82 and 536- 56. As cited from Bearn DR. Bonded orthodontic retainers: A review Am J Orthod Dentofac Orthop 1995 108:207-13.  [Google Scholar]

[4]EA Angle, Treatment of malocclusion of the teeth. 7th ed. Philadelphia: SS White Manufacturing Co., 1907. As cited from Bearn DR. Bonded Orthodontic Retainers: A review Am J Orthod Dentofac Orthop 1995 108:207-13.  [Google Scholar]

[5]CA Hawley, A removable retainer. Int J Orthod. 1919;2:291-8. As cited from Bearn DR. Bonded Orthodontic Retainers: A review Am J Orthod Dentofac Orthop 1995 108:207-13.  [Google Scholar]

[6]J Artun, AT Spadafora, PA Shapiro, RW McNeill, MK Chapko, Hygiene status associated with different types of bonded orthodontic canine to canine retainers J Clin Periodontol 1987 14:89-94.  [Google Scholar]

[7]BU Zachrisson, The bonded lingual retainer and multiple spacing of anterior teeth J Clin Orthod 1983 17:838-44.  [Google Scholar]

[8]T Uysal, A Baysal, S Usumez, M Ulker, Microleakage between composite-wire and composite-enamel interfaces of flexible spiral wire retainers. Part 1: comparison of three composites Eur J Orthod 2009 31:647-51.  [Google Scholar]

[9]DR Bearn, Bonded Orthodontic Retainers: A review Am J Orthod Dentofac Orthop 1995 108:207-13.  [Google Scholar]

[10]A Baysal, T Uysal, M Ulker, S Usumez, Effects of high-intensity curing lights on microleakage under bonded lingual retainers Angle Orthod 2008 78:1084-88.  [Google Scholar]

[11]DR Bearn, JF McCabe, PH Gordon, JC Aird, Bonded orthodontic retainers: The wire- composite interface Am J Orthod Dentofac Orthop 1997 111:67-74.  [Google Scholar]

[12]S Usumez, T Buyukyilmaz, A Karaman, Effect of a fast halogen and a plasma arc light on the surface hardness of orthodontic adhesives for lingual retainers Am J Orthod Dentofac Orthop 2003 123:641-48.  [Google Scholar]

[13]BU Zachrisson, Clinical experience with direct-bonded orthodontic retainers Am J Orthod Dentofac Orthop 1997 71:440-48.  [Google Scholar]

[14]EH Dahl, BU Zachrisson, Long-term experience with direct-bonded lingual retainers J Clin Orthod 1991 25:619-32.  [Google Scholar]

[15]TJ Gillgrass, DT Millet, SL Creanor, D MacKenzie, J Bagg, WH Gilmour, RH Foye, Flouride release, microbial inhibition and microleakage pattern of two orthodontic band cements J Dent 1999 27:455-61.  [Google Scholar]

[16]JW James, BH Miller, JD English, LP Tadlock, PH Buschang, Effects of high speed curing devices on shear bond strength and microleakge of orthodontic brackets Am J Orthod Dentofac Orthop 2003 123:555-61.  [Google Scholar]

[17]S Arikan, N Arhun, A Arman, SB Cahreti, Microleakage beneath ceramic and metal brackets photopolymerized with LED or conventional light curing units Angle Orthod 2006 76:1035-40.  [Google Scholar]

[18]A Yagci, T Uysal, H Ertas, M Amasyali, Microleakage between composite/wire and composite/enamel interfaces of flexible spiral wire retainers: direct versus indirect application methods Orthod Craniofac Res 2010 13:118-24.  [Google Scholar]

[19]RP Schulz, RB Mayhew, LJ Oesterle, WP Pierson, Bond strengths of three resin systems used with brackets and embedded wire attachments Am J Orthod Dentofac Orthop 1985 87:75-80.  [Google Scholar]

[20]T Uysal, M Ulker, A Baysal, S Usumez, Different lingual retainer composites and the microleakage between enamel-composite and wire-composite interfaces Angle Orthod 2008 78:941-46.  [Google Scholar]

[21]NA Oztruk, A Usumez, B Ozturk, S Usumez, Influence of different light is on microleakage of class V composite resin restorations J Oral Rehabil 2004 31:500-04.  [Google Scholar]

[22]M Ferrari, F Garcia-Godboy, Sealing ability of new generation adhesive restorative materials placed on vital teeth Am J Dent 2002 15:117-28.  [Google Scholar]

[23]DL Foek, M Ozcan, E Krebs, A Sandham, Adhesive properties of bonded orthodontic retainers to enamel: stainless steel wire vs fiber-reinforced composites J Adhes Dent 2009 11:381-90.  [Google Scholar]

[24]A Baysal, T Uysal, M Ulker, S Usumez, Effects of high-intensity curing lights on microleakage under bonded lingual retainers Angle Orthod 2008 78:1084-88.  [Google Scholar]