1. Reader, Department of Conservative Dentistry and Endodontics, Rural Dental College, Loni, Rahata, Maharashtra, India. 2. Senior Lecturer, Department of Oral Medicine and Radiology, Rural Dental College, Loni, Maharashtra, India. 3. Reader, Department of Conservative Dentistry and Endodontics, Rural Dental College, Loni, Maharashtra, India. 4. Professor and Head, Department of Conservative Dentistry and Endodontics, Rural Dental College, Loni, Maharashtra, India. 5. Professor, Department of Conservative Dentistry and Endodontics, RKDF Dental College, Bhopal, India.

Correspondence Address :
Dr. Basawaraj Channabasappa Biradar,
525/3/25, PMT Loni, Tal; Rahata, Ahmadnagar Dist, Loni-413736, Maharashtra, India.
E-mail: dr.basawaraj@rediffmail.com

Abstract

Introduction: Root canal treatment is a standard procedure for pulpal diseases and dental injuries. Working length determination is significantly important for successful outcome of root canal treatment.

Aim: The aim of this in vivo study was to evaluate the effect of instrument Size and Type on the accuracy of Electronic Apex Locator (EAL) on upper premolars.

Materials and Methods: One hundred and twenty root canals from 98 patients scheduled for endodontic treatment were included in this study and informed consent was obtained. Electronic measurements were made using Root ZX apex locator with stainless steel ISO k-file #8, #10, #15 and Nickel Titanium (NiTi) ISO k-file #8, #10, #15 in sequence and also radiographic length was measured. Statistical analysis was analysed with One-way ANOVA and Post-Hoc Tukey HSD tests.

Results: It was found that a highly significant difference was found between Ingle’s method and apex locator measured with stainless steel and NiTi #8 files and significant difference with Ingle’s method and apex locator measured with NiTi#10. There was no significant difference found between Ingle’s method and apex locator measured with stainless steel and NiTi #15 files and stainless steel #10 file.

Conclusion: Stainless steel files showed more accurate results compared to their corresponding NiTi files. This study has concluded that the use of steel instruments whose size corresponds to master apical file brings the best results.

Keywords

Ingle’s method, NiTi files, Stainless steel files, Working length

How to cite this article :

Basawaraj Channabasappa Biradar, Sudharani Basawaraj Biradar, Sai S Kalyan, Rashmikumar B Vora, Arvind MS. CLINICAL EVALUATION OF EFFECT OF INSTRUMENT SIZE AND TYPE ON THE ACCURACY OF ELECTRONIC APEX LOCATOR ON UPPER PREMOLARS. Journal of Clinical and Diagnostic Research [serial online] 2017 November [cited: 2017 Nov 22 ]; 11:ZC01-ZC04. Available from
http://www.jcdr.net/back_issues.asp?issn=0973-709x&year=2017&month=November&volume=11&issue=11&page=ZC01-ZC04&id=10745

DOI and Others

DOI: 10.7860/JCDR/2017/31271.10745

Date of Submission: Jul 01, 2017
Date of Peer Review: Aug 12, 2017
Date of Acceptance: Oct 03, 2017
Date of Publishing: Nov 01, 2017

FINANCIAL OR OTHER COMPETING INTERESTS: None.

JCDR is now Monthly and more widely Indexed .
  • PubMed Central® (PMC)New
  • Academic Search Complete Database
  • Chemical Abstracts Service
  • Directory of Open Access Journals (DOAJ)
  • EBSCOhostNew
  • Embase & EMbiology
  • Google Scholar
  • HINARI Access to Research in Health Programme
  • Indian Science Abstracts (ISA)
  • Journal seek Database
  • Open J-Gate
  • Popline (reproductive health literature)
  • SCOPUS
  • www.omnimedicalsearch.com